G. Display functions and programming possibilities
LED 6 is flashing.
With button or the 'offset learned
power limit' can be set in steps from 2
(most sensitive value) to 16 (according
to table).
Save your setting with programming
button .
The control unit changes automatically
to the programming of 'operator speed'.
4. Programming 'offset learned power limit'
Attention!
The learning power limit is set automatically.
Only change it if necessary (error No. 28)
When increasing the set value the offset in OPEN and
CLOSE direction is increased and thus the sensitivity of
the learning power limit is reduced.
Attention!
Always test the max. allowed operating forces according to
EN 12445 and EN 12453!